Stainless S-7 Reusable Concrete Anchor

ASTM A193 (304) B8 Class 1

Diameter
& Threads
per Inch
Ultimate Strength
Inner Stud
(fu)
Ultimate Strength
Outer Stud
(fu)
Nominal
Shear
Strength of
Outer Thread
(Vsa)
Torque Ft-Lbs Minimum
Embedment
(3000 PSI – f’c)
Minimum
Embedment
(6500 PSI – f’c)
Cone
& Shell
Length
(B)
Exterior
Thread
Length
(C)
Part
Number
To
Expand
Shell
On Nut
for
Tension
1/2” – 13
(13 mm)
3.93 kips
(17.5 kN)
10.6 kips
(47.3 kN)
6.38 kips
(28.4 kN)
10 10 3”
(77 mm)
2”
(51 mm)
1-1/4”
(32 mm)
1-1/2”
(38 mm)
S7U-3041-04
3/4” – 10
(19 mm)
10.6 kips
(47.2 kN)
25 kips
(111 kN)
15 kips
(66.7 kN)
50 60 5”
(127 mm)
4”
(102 mm)
1-3/4”
(45 mm)
1-3/4”
(45 mm)
S7U-3041-06
1” – 8
(25 mm)
17.0 kips
(75.6 kN)
45.5 kips
(202 kN)
27.3 kips
(121 kN)
75 170 7”
(178 mm)
6”
(153 mm)
2-9/16”
(65 mm)
2-1/2”
(64 mm)
S7U-3041-08

1)Minimum embedment depths reflect values for ductile steel failure of the anchor in accordance with ACI 318 for 3000 and 6500 PSI concrete, respectively.
(2)Use the lesser strength of the outer or inner stud capacity for anchor structural capacity in design.
(3)For Type C anchor applications, please contact your Williams representative to determine the capacity of the cable hole.