R1V High Impact Spin-Lock Concrete Anchor
|
|
|
|
|
|
 |
|
|
 |
|
|
The R1V Spin-Lock Mechanical Concrete Anchor is often specified for applications in extreme cold temperatures or if the anchor may be exposed to impact loading.
|
|
|
 |
|
|
R1V Structural Properties
| Yield Stress |
Ultimate Stress |
Elongation in
20 Bar Dia. |
Reduction
of Area |
Charpy at
-20º F' (-29º C) |
105 KSI
(723 Mpa) |
125 KSI (861 Mpa) |
16% |
50% |
20 ft/lbs
(27 Joules) |
|
|
|
 |
|
R1V High Impact Spin-Lock Concrete Anchor - ASTM A-193 Grade B-7
Dia. &
Threads
Per in.
|
Recomm.
Design Load
at 2:1 Safety
Factor
|
Maximum
Working
Load
to Yield
|
Average
Ultimate
Strength
|
Ultimate
Shear
Strength |
Drill
Hole
Dia.
(1) |
Type
Head
Ass'y |
Torque ft.-lbs. |
Min. Embed.
Depth in
3000 PSI
Concrete |
Part
Number
|
To Expand
Shell
(2) |
On Nut
for
Tension |
1/2 - 13
(12 mm) |
9 kips
(40.0 kN) |
15 kips
(66.7 kN) |
18 kips
(80.0 kN) |
10.8 kips
(48 kN) |
1-1/4"
(32 mm) |
A 10 |
50 ft.-lbs.
(50*) |
85 |
7"
(178 mm) |
R1V04A10 |
3/4" - 10
(20 mm) |
21 kips
(93.3 kN)
|
36 kips
(160 kN)
|
42 kips
(187 kN)
|
25.2 kips
(112 kN)
|
1-3/4"
(44 mm)
|
C 14
|
210 ft.-lbs.
(250*)
|
250
|
12"
(305 mm) |
R1V06C14
|
1" - 8
(25 mm) |
38 kips
(169 kN)
|
64 kips
(285 kN)
|
76 kips
(338 kN)
|
45.6 kips
(203 kN)
|
1-3/4"
(44 mm)
|
C 14
|
500 ft.-lbs.
(600*)
|
550
|
16"
(406 mm) |
R1V08C14
|
1-1/4" - 7
(32 mm) |
61 kips
(273 kN)
|
102 kips
(454 kN)
|
122 kips
(543 kN)
|
73 kips
(326 kN)
|
2-1/4"
(57 mm)
|
C 18
|
750 ft.-lbs.
(1600*)
|
1000
|
22"
(559 mm) |
R1V10C18
|
1-3/8" - 8
(35 mm) |
77.5 kips
(344 kN)
|
129 kips
(573 kN)
|
154 kips
(684 kN)
|
92.4 kips
(411 kN)
|
2-1/2"
(65 mm)
|
B 20
|
750 ft.-lbs.
(1600*)
|
1725
|
24"
(610 mm) |
R1V11B20
|
1-1/2" - 6
(38 mm) |
88 kips
(391 kN)
|
148 kips
(658 kN)
|
176 kips
(783 kN)
|
106 kips
(470 kN)
|
3"
(76 mm)
|
B 24
|
1000 ft.-lbs.
(1700*)
|
Note (3)
|
26"
(660 mm) |
R1V12B24
|
1-3/4" - 5
(45 mm) |
99.5 kips
(443 kN)
|
199 kips
(885 kN)
|
237 kips
(1054 kN)
|
142 kips
(632 kN)
|
3"
(76 mm)
|
B 24
|
1000 ft.-lbs.
(1700*)
|
Note (3)
|
29"
(737 mm) |
R1V14B24
|
2"-6
(51mm) |
165 kips
(733 kN)
|
278 kips
(1236 kN)
|
330 kips
(1467 kN)
|
198 kips
(880 kN)
|
3-1/2"
(89 mm)
|
C 28
|
1000 ft.-lbs.
(4000*)
|
Note (3)
|
35"
(889 mm) |
R1V16C28
|
|
|
|
|
|
NOTES:
(*) Do not exceed these numbers
(1) Care should be taken to drill a straight and properly sized hole.
(2) More torque may be required on long anchors or if the head assembly is next to rebar. Consult your Williams Representative for more specific details.
(3) Stress to desired tensile load using a hollow ram hydraulic jack. Consult your Williams Representative.
(4) Full ultimate strength of anchor can be achieved at listed embedment depth, provided there are no edge or spacing effects on the anchor.
WILLIAMS reserves the right to ship full length or coupled units as necessary.
All above torque values are used for clean, dry (un-greased) threads. For greased thread torque values, contact your local Williams representative.
|
|
|
|
 |
|
 |
|
|
|
|
 |
|
|
|
Williams Form Engineering Corp. All rights reserved. |
|